Skip to page content

AEGLIX MIND

Intelligence for Africa and the Gulf

AEGLIX vulnerability intelligence

CVE-2021-38406

HIGH · CVSS 7.8 · Analyzed

Published: 2021-09-17 · Updated: 2026-06-17 · Source: NVD

Vulnerability overview

Delta Electronic DOPSoft 2 (Version 2.00.07 and prior) lacks proper validation of user-supplied data when parsing specific project files. This could result in multiple out-of-bounds write instances. An attacker could leverage this vulnerability to execute code in the context of the current process.

Severity and scoring

CVSS score
7.8 · HIGH
CVSS version
3.1
CVSS vector
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Weaknesses
CWE-787

CVSS measures technical severity; it does not establish whether this vulnerability is being exploited in your environment.

Known exploitation and remediation

Listed in CISA’s Known Exploited Vulnerabilities catalog.

Affected product
Delta Electronics · DOPSoft 2
Added to catalog
2022-08-25
Required action
The impacted product is end-of-life and should be disconnected if still in use.
CISA remediation due date
2022-09-15

CISA deadlines apply to the organizations covered by its directives. Confirm your own remediation requirements.

Verify affected versions and patch availability in the vendor advisory before making changes.

Affected products and versions

  • cpe:2.3:a:deltaww:dopsoft:*:*:*:*:*:*:*:*

    From (inclusive): 2.00

    Through (inclusive): 2.00.07

These are NVD CPE applicability entries. Some products depend on configuration conditions; consult the official record to confirm applicability.

Advisories and references

Explore official sources

Read the official NVD record ↗

Explore the CISA catalog ↗

Back to CVE intelligence