Skip to page content

AEGLIX MIND

Intelligence for Africa and the Gulf

AEGLIX vulnerability intelligence

CVE-2026-5494

HIGH · CVSS 7.8 · Analyzed

Published: 2026-04-11 · Updated: 2026-10-26 · Source: NVD

Stored catalog record

Source record retrieved 2026-10-28T10:18:49.856012+00:00. Scheduled imports handle updates; this page does not assert that the provider was queried just now.

Vulnerability overview

Labcenter Electronics Proteus PDSPRJ File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Labcenter Electronics Proteus. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the processing of PDSPRJ files. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-25719.

Patch review priority

Assess exposure and vendor guidance

  • No higher-priority signal is available in the current stored evidence.

FIRST EPSS: 0.28% · percentile 20.8 · score date 2026-10-27.

EPSS estimates probability of exploitation in the next 30 days. It does not measure your exposure or prove exploitation. The elevated threshold is 10%; CISA KEV takes precedence. About FIRST EPSS ↗

Severity and scoring

CVSS score
7.8 · HIGH
CVSS version
3.0
CVSS vector
CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Weaknesses
CWE-787

CVSS measures technical severity; it does not establish whether this vulnerability is being exploited in your environment.

Known exploitation and remediation

Not listed in the CISA catalog retrieved for this record. This does not establish that exploitation has not occurred.

Verify affected versions and patch availability in the vendor advisory before making changes.

Affected products and versions

  • cpe:2.3:a:labcenter:proteus:8.17:sp5:*:*:*:*:*:*

These are NVD CPE applicability entries. Some products depend on configuration conditions; consult the official record to confirm applicability.

Advisories and references

Explore official sources

Read the official NVD record ↗

Explore the CISA catalog ↗

Back to CVE intelligence