CVE-2026-99091

UNSCORED · Received

Published: 2026-10-26 · Updated: 2026-10-26 · Source: NVD

Stored catalog record

Source record retrieved 2026-10-28T10:27:16.764465+00:00. Scheduled imports handle updates; this page does not assert that the provider was queried just now.

Vulnerability overview

In the Linux kernel, the following vulnerability has been resolved: Bluetooth: MGMT: Fix status of pending commands flushed on power off cmd_complete_rsp() receives a struct cmd_lookup and, for a pending command that has no cmd_complete callback, falls through to cmd_status_rsp(cmd, data). cmd_status_rsp() reads data as a u8 *, so the status sent comes from the first byte of match->sk's representation, not from match->mgmt_status. commit f53e1c9c726d ("Bluetooth: MGMT: Fix possible crash on mgmt_index_removed") changed the callers' data from &status to &match and updated the cmd_complete branch to match->mgmt_status, but left the fall-through passing data unchanged. In mgmt_index_removed() match->sk is NULL, so every such command is answered with status 0x00 (Success) instead of MGMT_STATUS_INVALID_INDEX. In __mgmt_power_off() it is NULL too, unless a Set Powered command was pending: then settings_rsp() has stored that command's socket in match->sk, and the byte sent comes from the socket pointer. Either way the status the caller set, MGMT_STATUS_NOT_POWERED (or MGMT_STATUS_INVALID_INDEX when the device is being unregistered), is lost. Pass the status the callers set. This was seen on a QCA9377 laptop: bluetoothd's Start Discovery, pending when the adapter was powered off, was answered with Command Status 0x00 and no parameters, and bluetoothd 5.72 crashed on the zero-length success. BlueZ master has since added the length check on that path ("adapter: Fix crash on short start discovery reply", BlueZ a734b06059cb), but userspace should still be told Not Powered, not Success. Tested on Ubuntu 7.0.0-31 with a virtual controller (hci_vhci): power off is held in HCI Write Scan Enable while a Start Discovery is submitted, and the flush answers it with status 0x00 before this change and 0x0f (Not Powered) after.

Patch review priority

Assess exposure and vendor guidance

  • No higher-priority signal is available in the current stored evidence.

FIRST EPSS: 0.16% · percentile 5.6 · score date 2026-10-27.

EPSS estimates probability of exploitation in the next 30 days. It does not measure your exposure or prove exploitation. The elevated threshold is 10%; CISA KEV takes precedence. About FIRST EPSS ↗

Severity and scoring

CVSS score
Not scored · UNSCORED
CVSS version
Not supplied
CVSS vector
Not supplied
Weaknesses
Not supplied

CVSS measures technical severity; it does not establish whether this vulnerability is being exploited in your environment.

Known exploitation and remediation

Not listed in the CISA catalog retrieved for this record. This does not establish that exploitation has not occurred.

Verify affected versions and patch availability in the vendor advisory before making changes.

Affected products and versions

NVD has not supplied affected-version configurations for this record. Check the vendor references below.